Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Modell: KNM6
Marke: Korlen
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: Mccb
Poles Number: 2
Type: Circuit Breaker
Function: Overcurrent Protection
Certification: Ce;cb;sni;nf;tse;semko
Rated Working Current: 6a To 63a
Rated Working Voltage: 690v And Below
Production Standard: Iec60947-2;gb14048.2
Verpakung: Karton
Produktivität: 5000000PCS/Year
Transport: Ocean,Land,Air
Ort Von Zukunft: Wenzhou; Zhejiang; China
Zertifikate : CE,CB;VDE;
HS-Code: 8536200000
Hafen: Ningbo,ShangHai
Zahlungsart: L/C,T/T,D/P,Paypal
Anwendungsbereich
Der geformte Fallschalter der KNM5 -Serie Die Nenndämmspannung des Leistungsschalters beträgt bis zu 1000 V. Es ist für AC 50Hz geeignet, bewertet
Arbeitsspannung bis 690 V, bewertetes Arbeitsstrom von 10a bis 800A in der Verteilungsnetzschaltung, verwendet, um Strom zu verteilen und die Linie zu schützen und
Stromausrüstung von Überlastung, Kurzschluss, Spannungsschäden und anderen Fehlern. Gleichzeitig kann es auch als ursprünglich selten verwendet werden
Start des Motors und der Überlastung, des Kurzschlusses und des Unterspannungsschutzes. Der Leistungsschalter hat die Eigenschaften von kleiner Größe, hohem Brechen, kurzem Lichtbogen usw. und ist ein ideales Produkt für Benutzer. Der Leistungsschalter
ist vertikal installiert (dh, es ist vertikal installiert, und die Klasse kann horizontal horizontal installiert werden. Dieses Produkt entspricht EC60947-2, GB14048.2 und anderen Standard
Gekapselter Leistungsschalter
Kleine geformte Kofferschalter
Elektrogefühlsschalter
Automatisch geformter Fallschalter
McCB
No. |
Testing current name |
I/In |
Assumed time |
Starting situation |
1 |
Assumed untripping current |
1.05 |
2h(In>63A), 1h(In≤63A) |
Cold state |
2 |
Assumed tripping current |
1.30 |
2h(In>63A), 1h(In≤63A) |
Start right after the number 1 test |
Type | Frame | Rated |
Rated working voltage (V) |
Rated nsulation voltage |
Rated limiting short-circuit breaking ability KA400V |
Rated opearating short- ircuit breaker ability KA 400V |
Outline | Mount | ng | ||
d | mension | dimens | ons | ||||||||
current | current | ||||||||||
L |
W 3Pi4P |
H | AB | 4-Φd | |||||||
KNM1-63L | (6).1016, | 25 | 18 | 135 | 78 | 73.5 | |||||
KNM1-63M | 40,50,63 | 50 | 35 | 135 | 78/103 | 81.5 | |||||
KNM1-100L | 35 | 18 | 150 | 92 | 68 | ||||||
(10).1620, | |||||||||||
KNM1-100M | 100 | 25,32,40,50, | AC40OV | 690V | 50 | 35 | 30129 | Φ4.5 | |||
63,80100 | |||||||||||
KNM1-100H | 85 | 50 | |||||||||
KNM1-160L | 35 | 22 | 165 | 107 | 86 | ||||||
KNM1-160M | 160 | 100125, | AC40OV | 690V | 50 | 35 | 35 126 | Φ4.5 | |||
140160 | |||||||||||
165 | 107/142 | 103 | |||||||||
KNM1-160H | 85 | 50 | |||||||||
KNM1-225L | 35 | 22 | 165 | 107 | 86 | ||||||
100125140 | |||||||||||
KNM1-225M | 225 | 160180200 | AC400V | 690V | 50 | 35 | 35 126 | Φ4.5 | |||
KNM1-225H | 85 | 50 | |||||||||
KNM1-400L | 42 | 35 | 257 | 150/198 | 105 | 44 194 | Φ7 | ||||
KNM1-400M | 400 |
225250315 350,400 |
AC40OV | 690V | 65 | 50 | |||||
257 | 50/98 | 05 | |||||||||
KNM1-400H | 100 | 65 | |||||||||
KNM1-630L | 42 | 35 | 270 | 182/240 | 110 | 58 200 | Φ7 | ||||
KNM1-630M | 630 | 400500630 | AC400V | 690V | 65 | 50 | |||||
KNM1-630H | 100 | 65 | |||||||||
KNM1-800M | 75 | 50 | |||||||||
800 | 630700800 | AC4OOV | 690V | 275 | 210 | 103 | 70 243 | ||||
KNM1-800H 100 65 |
KNM5H Frame class 125 160 250 Item model KNM5H-125 KNM5H-160 KNM5H-250 |
||||||
Rated current In(A) |
10,16,20,32,40,50, 63,80,100,125 |
10,16,20,32,40,50,63, 80,100,125,140,160 |
100,125,140,16 200,225,2 |
|||
Rated voltage Rated insulation voltage Ultimate short-circuit breaking capacity AC40OV (KA)Icu/lcs Electrical life Mechanical life |
AC4OOV AC1000V |
AC40OV AC1000V |
AC40OV AC1000V |
|||
35/25 | 70/50 | 85/50 | ||||
6000 | 3000 | 3000 | ||||
9000 | 7000 | 7000 | ||||
2P Outline dimensions 3P (mm) 4P 2P |
60-155-68 | 60-155-88 | ||||
90-155-68 120-155-68 |
90-155-88 120-155-88 |
105-165- | ||||
140-165- | ||||||
055 | 1.1 | |||||
Weight(KG) 3P 065 12 17 4P 08 15 21 KNM5E Frame class 160 250 630 Item model KNM5E-160 KNM5E-250 KNM5E-630 |
||||||
Rated current | In(A) | 10,16,20,32,40,50. | 100,125,140,160,180, | 250,315,350,400, | ||
63,80,100,125,140,160 | 200,225,250 | |||||
Rated volt | ge | AC40OV | AC40OV |
, AC40OV |
||
Rated insulation | voltage | AC1000V | AC1000V | AC1000V | ||
Ultimate short-circuit | AC400V | 70/50 | 85/50 | 85/50 | ||
breaking capacity | ||||||
(KA)lcu/lcs | ||||||
Electrical life | 1500 | 1000 | 1000 | |||
Mechanical l | fe | 7000 | 7000 | 4000 | ||
Outline dimensions | 3P | 90-155-88 | 105-165-88 | 140-257-103 | ||
(mm) | 4P | 120-155-88 | 140-165-88 | 185-257-103 | ||
Weight(KG) | 3P | 18 | 21 | 57 | ||
4P | 23 | 26 | 75 | |||
KNM5LY Frame class 125 160 250 |
||||||
Item model KNM5LY-125 KNM5LY-160 KNM5LY-250 10,16,20,32,40,50. 10,16,20,32,40,50,63, 100,125,140,160, Rated current In(A) 63,80,100,125 80,100,125,140,160 180,200,225,250 Rated voltage AC40OV AC40OV AC40OV |
||||||
Rated insulation voltage Ultimate short-circuit breaking,capacity AC40OV (KA)lcu/lcs Electrical life Mechanical life |
AC690V | AC690V | AC690V | |||
35/25 | 70/50 | 85/50 | ||||
6000 | 6000 | 3000 | ||||
9000 | 9000 | 7000 | ||||
Undelay Rated residual operationcurrent(IAn) Delay Undelay Maxim breaking ime(s) Delay(2lAn) |
30,100,500(Adjustable) | 30,100,500(Adjustable) | 30,100,500(Adjustable) | |||
100,300,500(Adjustable) 0.1 |
100,300,500(Adjustable) 0.1 |
100,300,500(Adjustable) 0.1 |
||||
0.45,1.0,2.0(Adjustable) | 0.45,1.0,2.0(Adjustable) | 0.45,1.0.2.0(Adjustable) | ||||
2P Outline dimensions 3P (mm) 4P |
50-130-68 75-130-68 |
60-155-68 90-155-88 |
105-165-88 | |||
100-130-68 | 120-155-88 | 140-165-88 | ||||
2P Weight(KG) 3P 4P |
0.55 0.65 |
0.75 | ||||
1.2 2.1 | ||||||
0.8 | 1.5 2.6 |
Produktionskapazität: Wir haben mehr als 1500 Arbeitnehmer und 100 Experteningenieure, die in weniger als 5 Tagen einen Container unserer Produkte produzieren können. Die jährliche Produktion ist wie folgt; MCB 15 million poles, RCCB (thermal type) 2 million poles,( 58586566, 58586481, 58586421, 58584297, 58584119, 58584025, 58583980, 58583777, 58583684, 58583534, 58583405,magnetic type) 800 thousand pole. Die Produktion anderer Produkte liegt auch im Bereich von mindestens weniger als Tausenden von Polen pro Jahr.
Preisgestaltung: Wir bieten den besten Preis, um die Anforderungen aller Kunden zu erfüllen, abhängig von der Qualität und der Anzahl der geforderten Quantitäten.
Produktgruppe : Gekapselter Leistungsschalter > Kompaktleistungsschalter der Serie KNM5
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.