Modell: KNLE1-100
Marke: Korlen
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: Elcb
Poles Number: 2
Type: Circuit Breaker
Function: Conventional Circuit Breaker
Certification: Ce
Rated Worling Current: 63;80;100a
Frame: 100a
Maximum Operating Time: I△n T≤0.1s , 5i△n T≤0.04
Sensibility: Ac Type
Rated Working Voltage: 240/415v
Verpakung: Karton
Produktivität: 5000000PCS/Year
Transport: Ocean,Land,Air
Ort Von Zukunft: Wenzhou; Zhejiang; China
Zertifikate : CE,CB;VDE;
HS-Code: 8536200000
Hafen: Ningbo,ShangHai
Zahlungsart: L/C,T/T,D/P,Paypal
RCBO ist der Reststromschalter mit Überstromschutz. Grundsätzlich führt es die Funktionen von MCB und RCCB zusammen. Dies bedeutet, dass es verwendet werden kann, um die Linie vor überlasteten und kurzübersetzten und seltenen Umstellung der Linie in der normalen Situation zu schützen.
Die Serie KNLE1-100 Leckschalter gilt für drei Phasen mit bis zu 63A für drei Phasen von bis zu 230 V oder bis zu 400 V, um als Leckschutz zu fungieren. Wenn jemand einen Elektroschock erhält oder der Leckstrom an der Linie den festgelegten Wert überschreitet, kann der Leistungsschalter die Leistung automatisch in 0,2s brechen, um den Körper und die Ausrüstung zu schützen.
Die Serie KNLE1-100 Leckschalter führt den Überlast- und Kurzschlussschutz durch und führt auch die niedrige Frequenz des Schaltungsumschusses unter normalem Zustand durch. Dieses Produkt entspricht der Anforderung von GB16917.1 -Standards.
Erdungslauchschalter
Leckageschalter
ELCB
Frame class | 100A |
Rated working voltage | 240/415V |
Rated frequency | 50/60Hz |
Rated working current | 63,80,100A |
Rated residual operating current | 0.03,0.1A |
Rated residual un-operating current | 0.015,0.05A |
Sensibility | AC Type |
Maximum operating time | IΔn t≤0.1s , 5IΔn t≤0.04 |
Instant release type | C type |
Limiting value of un-operating current | 6In |
Rated limiting short-circuit current | 6000A |
Pole number | 1P+N,2P,3P,3P+N |
Mechanical life | 8000 |
Electric life | 4000 |
Sequence NO . |
Release |
Test current I/In |
Start state |
Tripping time |
Expected restlt |
1 | c | 1.13In | Cold state | t≤2h | Not tripping |
2 | c | 1.45In |
Start right after the serial NO . 1 test |
t<2h | Tripping |
3 | c | 2.55In | Cold state | 1s<t<120s | Tripping |
4 | c | 5In | Cold state | t≤0.1s | Not tripping |
5 | c | 10In | Cold state | t<0.1s | Trippi |