Modell: KNR8
Marke: Korlen
Theory: Thermal Relay
Size: Miniature
Action Principle: Electronic Type
Protective Characteristics: Other
Load: Micro Power Relay
Number Of Pole: Other
Electricity Type: Ac
Phase: Other
Usage: Lathe Relay
Type: Electric Parameter Relay
Rated Frequency: 50/60hz
Rated Working Current: 25;36;93a
Standards: Iec947-4;vde0660;gb14048.4
Rated Current: 0.1-400a
Rated Insulation Voltage: 660v
Verpakung: Karton
Produktivität: 500000PCS/Year
Transport: Ocean,Land,Air
Ort Von Zukunft: Wenzhou; Zhejiang; China
Zertifikate : CE;CB;
HS-Code: 8536200000
Hafen: Ningbo,ShangHai
Zahlungsart: L/C,T/T
Strukturfunktion
● Senies Überlastungsrelais des thermischen Metallmodus, Triping Class ist 10a;
● Setzen Sie den aktuellen kontinuierlichen einstellbaren Gerät ein;
● Auslöseranzeige;
● Testknopf;
● Taste mit Handbetrieb und automatischer Reset -Taste zurücksetzen.
● Haben Sie ein Paar NO- und NC -Isolationskontakt in Elektrizität;
● Installationsart: Unabhängig installieren oder den AC -Schütz anschließen können
Reed Relay Overload Relais der KNR8 -Serie ist für 50 Hz/60 Hz geeignet, die Spannung mit einer Spannung von 690 ~ 1000 V und einem Nennstrom von 0,1 ~ 400A in der Hauptkreislauf der langjährigen Arbeiten geeignet. Es wird verwendet, um den Asynchronmotor mit dreiphasiger Wechselstrom vor Überlastung und offener Phase zu schützen.
Diese Produkte Thermal-Relais -Konformität mit IEC947-4, VDE0660, GB14048.4 Standards. Reed Relais
Thermalrelais
Relais verriegelt
Reed Relais
Polarisiertes Relais
Arbeitesverdacht
● Die Altituelde sollte nicht höher als 2000 m sein.
● Die Umgebungstemperatur: -25 ℃ ~ 55 ℃;
● Die relative Luftfeuchtigkeit: Wenn +25 ℃, sollte die relative Luftfeuchtigkeit nicht mehr als 90%betragen.
Feature
● Senies Überlastungsrelais des thermischen Metallmodus, Triping Class ist 10a;
● Setzen Sie den aktuellen kontinuierlichen einstellbaren Gerät ein;
● Auslöseranzeige;
● Testknopf;
● Taste mit Handbetrieb und automatischer Reset -Taste zurücksetzen.
● Haben Sie ein Paar NO- und NC -Isolationskontakt in Elektrizität;
● Installationsart: Unabhängig installieren oder den Wechselstromkontator anschließen.
Thermalrelais
Relais verriegelt
Reed Relais
Polarisiertes Relais
Parameter und technisches Datum
Type |
Sphere of |
Fuse specification (A) |
|
|
|
IEC947-4 |
|
|
|
[1" |
[2" |
KNR8-50 |
0.1-0.16 |
35 |
0.5 |
|
0.16-0.25 |
|
1 |
|
1.25-0.4 |
|
1.6 |
|
0.4-0.63 |
|
2 |
|
0.63-1 |
|
4 |
|
0.8-1.25 |
|
4 |
|
1-1.6 |
|
6 |
|
1.25-2 |
|
6 |
|
1.6-2.5 |
|
6 |
|
2-3.2 |
|
10 |
|
2.5-4 |
|
10 |
|
3.2-5 |
|
20 |
|
4-6.3 |
|
16 |
|
5-8 |
|
16 |
|
6.3-10 |
|
25 |
|
8-12.5 |
|
25 |
|
10-14.5 |
|
25 |
KNR8-52 |
0.1-0.16 |
63 |
0.5 |
|
0.16-0.25 |
|
1 |
|
0.25-0.4 |
|
1.6 |
|
0.4-0.63 |
|
2 |
|
0.63-1 |
|
4 |
|
0.8-1.25 |
|
4 |
|
1-1.6 |
|
6 |
|
1.25-2 |
|
6 |
|
1.6-2.5 |
|
6 |
|
2-3.2 |
|
10 |
|
2.5-4 |
|
10 |
|
3.2-5 |
|
16 |
|
4-6.3 |
|
16 |
|
5-8 |
|
20 |
|
6.3-10 |
|
25 |
|
8-12.5 |
|
25 |
|
10-16 |
|
35 |
|
12.5-20 |
|
35 |
|
16-25 |
|
50 |
KNR8-55 |
1-1.6 |
100 |
6 |
|
1.25-2 |
|
6 |
|
1.6-2.5 |
|
6 |
|
2-3.2 |
|
10 |
|
2.5-4 |
|
10 |
|
3.2-5 |
|
16 |
|
4-6.3 |
|
16 |
|
5-8 |
|
20 |
|
6.3-10 |
|
25 |
|
8-12.5 |
|
25 |
|
10-16 |
|
35 |
|
12.5-20 |
|
50 |
|
16-25 |
|
50 |
|
20-32 |
|
80 |
|
25-36 |
|
80 |
|
32-40 |
|
80 |
|
36-45 |
|
80 |
Type |
Sphere of |
Fuse specification (A) |
|
|
|
IEC947-4 |
|
|
|
[1" |
[2" |
KNR8-58 |
12.5-20 |
160 |
50 |
|
16-25 |
|
50 |
|
20-32 |
|
63 |
|
25-40 |
|
80 |
|
32-50 |
|
100 |
|
40-57 |
|
100 |
|
50-63 |
|
100 |
|
57-70 |
|
125 |
|
63-80 |
250 |
160 |
|
70-88 |
|
160 |
KNR8-60 |
55-80 |
250 |
160 |
|
63-90 |
|
160 |
|
80-110 |
315 |
200 |
|
90-120 |
|
224 |
|
110-135 |
|
224 |
KNR8-61 |
55-80 |
250 |
160 |
|
63-90 |
|
160 |
|
80-110 |
315 |
200 |
|
90-120 |
|
224 |
|
110-135 |
|
224 |
|
120-150 |
|
224 |
KNR8-59 |
0.1-0.16 |
25 |
0.5 |
|
0.16-0.25 |
|
1 |
|
0.25-0.4 |
|
1.6 |
|
0.4-0.63 |
|
2 |
|
0.63-1 |
|
4 |
|
0.8-1.25 |
|
4 |
|
1-1.6 |
|
6 |
|
1.25-2 |
|
6 |
|
1.6-2.5 |
|
6 |
|
2-3.2 |
|
10 |
|
2.5-4 |
|
10 |
|
3.2-5 |
|
16 |
|
4-6.3 |
|
16 |
|
5-8 |
|
16 |
|
6.3-10 |
|
16 |
|
8-12.5 |
35 |
25 |
|
10-16 |
63 |
35 |
|
12.5-20 |
63 |
50 |
|
16-25 |
63 |
50 |
|
20-32 |
80 |
63 |
|
25-40 |
125 |
80 |
|
32-40 |
160 |
100 |
|
40-57 |
160 |
125 |
|
50-63 |
160 |
125 |
KNR8-62 |
55-80 |
250 |
160 |
|
63-90 |
|
160 |
|
80-110 |
250 |
200 |
|
90-120 |
315 |
224 |
|
135-160 |
355 |
|
KNR8-66 |
80-125 |
500 |
250 |
|
125-200 |
|
315 |
|
160-250 |
|
400 |
|
200-320 |
|
400 |
|
250-400 |
800 |
500 |
Das Unternehmen hat gut erfahrene Belegschaft, von leitenden Ingenieuren und Technikern bis hin zu Fabrikarbeitern, die eine Gesamtbevölkerung von 1.500 Arbeitnehmern ausmachen. Das Unternehmen deckt eine Fläche von mehr als 50 Hektar Land ab. Die Baustelle ist mehr als 38000 Quadratmeter der modernen Industriezone. Korlen ist mit einem modernen, raffinierten Labor mit hoher Prüfungsausrüstung ausgestattet. Aufgrund unserer strikten Einhaltung gemäß den elektrischen Codierungssystemen jedes Landes hat es das Unternehmen gelungen, mehr als 20 nationale Patente zu erhalten, einschließlich anderer akkreditierter internationaler Zertifikate. Dies macht Korlen zu einer herausragenden Rolle bei der Herstellung elektrischer Schutzgeräte unter seinen Konkurrenten.
Produktgruppe : Thermisches Relais
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.